RS 485 Databus Cables 300/500V
FRL-MVB-02Y(ST)CH-IOS-xPyS, FRL-MVB-02YCH-OS-xPyS

Application :

  • 120 Ohm data transmission cables.

Construction :

  • Multipair Databus RS 485 Double screened Cable :
  • Conductors Stranded tin plated copper conductor according to IEC 60228 class 5(0.22mm2-1mm2).
    Insulation Cross linked Foam PE.
    Cable Element Twisted pair.
    Individual Screen Individual Aluminium Tape.
    Overall Screen Copper Wire Braid.
    Core Wrapping Plastic tape(s).
    Outer Sheath Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1.
  • A. Conductor

     

    B. Insulation

     

    C. Screen

     

    D. Sheath

  • Multipair Databus RS 485 Single screened Cable :
  • Conductor Stranded tin plated copper conductor according to IEC 60228 class 5(0.22mm2-1mm2).
    Insulation Cross linked Foam PE.
    Cable Element Twisted pair.
    Overall Screen Copper Wire Braid.
    Outer Sheath Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1.

Electrical & Mechanical Properties :

  • Nominal Voltage 300/500V
    Impedance 120Ω+/-15%
    Capacitance@1KHz 41nF/km
    Insulation Resistance 5000MΩ

Chemical & Environmental Properties :

  • EN 60684-2 No fluorine
    EN 50305; EN 60811-2-1 Resistance to mineral oil & fuel oil, acid & alkali
    EN 50305 Resistance to ozone

Fire Performance for rolling stock application :

  • EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
    DIN 5510-2 Protection level 1/2/3/4
    BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
    NF F 16-101 F0

Fire Performance for rolling stock application :

  • EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) Vertical flame propogation for a single insulated wire or cable
    EN 50266-2-4 + EN 50305; IEC 60332-3-24;
    NF C 32-070 2.2 (C1); VDE 0472 Teil 804
    Vertical flame spread of vertically mounted bunched wires or cables
    EN 50268-2; IEC 61034-2; NF C 32-073 ;
    NF C 20-902; NF F 16 101; VDE 0472 Teil 816
    Low Smoke Emission
    EN 50267-2-1; IEC 60754-1; NF C 32-074;
    NF C 20-454; VDE 0472 Teil 815
    Halogen Free

    EN 50267-2-2/3; IEC 60754-2; NF C 32-074;

    NF C 20-453; VDE 0472 Teil 813

    Low Corrosivity (Acidity & Conductivity)
    EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853
    Low Toxicity
    NF F 63 808; BS6853; NF F 16 101 Smoke index

FRL-MVB-02Y(ST)CH-IOS-xPyS 300/500V :

  • No.of pair
    x
    Nominal Cross Sectional Area
    y
    Number & Nominal
    Diameter of Strands
    Nominal Overall Diameter Nominal Weight
    mm2 No/mm mm kg/km
    1 0.22 7/0.2 4.5 58
    2 0.22 7/0.2 6.2 79
    4 0.22 7/0.2 6.5 118
    1 0.5 16/0.2 6.6 79
    2 0.5 16/0.2 9.0 105
    4 0.5 16/0.2 9.8 145
    1 0.75 24/0.2 9.5 115
    2 0.75 24/0.2 10.3 135
    4 0.75 24/0.2 11.6 182
    1 1 30/0.2 11.5 125
    2 1 30/0.2 12.5 150
    4 1 30/0.2 13.5 180

FRL-MVB-02YCH-OS-xPyS 300/500V :

  • No.of pair
    x
    Nominal Cross Sectional Area
    y
    Number & Nominal
    Diameter of Strands
    Nominal Overall Diameter Nominal Weight
    mm2 No/mm mm kg/km
    1 0.22 7/0.2 4.2 55
    2 0.22 7/0.2 5.9 75
    4 0.22 7/0.2 6.2 115
    1 0.5 16/0.2 6.3 75
    2 0.5 16/0.2 8.5 100
    4 0.5 16/0.2 9.4 140
    1 0.75 24/0.2 9.0 110
    2 0.75 24/0.2 9.7 130
    4 0.75 24/0.2 11.1 178
    1 1 30/0.2 11.0 120
    2 1 30/0.2 12.0 145
    4 1 30/0.2 13.0 175

 

Corona Resistant
Highly Flexible
UV Resistant
Ozone Resistant
Abrasion Retardant
Cold- resistant

 

Resistance To
Soldering Heat
Acid&Alkaline
Resistant
IRM 903
Fuel Oil Resistant
IRM 902
Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2)
IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1)
IEC60332-1-2/EN50265-2-1

 

Low Toxicity
NF X70-100/NF F63 808
TM1-04/BS 6853
Low Corrosivity
IEC60754-2/EN50267-2-2/3
NF C32-074/VDE 0472-813
Low Smoke Emission
IEC 61034-2 / EN 50268-2
NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1
NF C32-074//VDE 0472-815