RS 485 Databus Cables 300/500V
FRL-MVB-02Y(ST)CH-IOS-xPyS, FRL-MVB-02YCH-OS-xPyS
Application :
- 120 Ohm data transmission cables.
Construction :
- Multipair Databus RS 485 Double screened Cable :
-
Conductors Stranded tin plated copper conductor according to IEC 60228 class 5(0.22mm2-1mm2). Insulation Cross linked Foam PE. Cable Element Twisted pair. Individual Screen Individual Aluminium Tape. Overall Screen Copper Wire Braid. Core Wrapping Plastic tape(s). Outer Sheath Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1. -
A. Conductor
B. Insulation
C. Screen
D. Sheath
- Multipair Databus RS 485 Single screened Cable :
-
Conductor Stranded tin plated copper conductor according to IEC 60228 class 5(0.22mm2-1mm2). Insulation Cross linked Foam PE. Cable Element Twisted pair. Overall Screen Copper Wire Braid. Outer Sheath Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1.
Electrical & Mechanical Properties :
-
Nominal Voltage 300/500V Impedance 120Ω+/-15% Capacitance@1KHz 41nF/km Insulation Resistance 5000MΩ
Chemical & Environmental Properties :
-
EN 60684-2 No fluorine EN 50305; EN 60811-2-1 Resistance to mineral oil & fuel oil, acid & alkali EN 50305 Resistance to ozone
Fire Performance for rolling stock application :
-
EN 50306-2 Hazard levels HL1, HL2/HL3, HL4 DIN 5510-2 Protection level 1/2/3/4 BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II NF F 16-101 F0
Fire Performance for rolling stock application :
-
EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) Vertical flame propogation for a single insulated wire or cable EN 50266-2-4 + EN 50305; IEC 60332-3-24;
NF C 32-070 2.2 (C1); VDE 0472 Teil 804Vertical flame spread of vertically mounted bunched wires or cables EN 50268-2; IEC 61034-2; NF C 32-073 ;
NF C 20-902; NF F 16 101; VDE 0472 Teil 816Low Smoke Emission EN 50267-2-1; IEC 60754-1; NF C 32-074;
NF C 20-454; VDE 0472 Teil 815Halogen Free EN 50267-2-2/3; IEC 60754-2; NF C 32-074;
NF C 20-453; VDE 0472 Teil 813
Low Corrosivity (Acidity & Conductivity) EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 Low Toxicity NF F 63 808; BS6853; NF F 16 101 Smoke index
FRL-MVB-02Y(ST)CH-IOS-xPyS 300/500V :
-
No.of pair
xNominal Cross Sectional Area
yNumber & Nominal
Diameter of StrandsNominal Overall Diameter Nominal Weight mm2 No/mm mm kg/km 1 0.22 7/0.2 4.5 58 2 0.22 7/0.2 6.2 79 4 0.22 7/0.2 6.5 118 1 0.5 16/0.2 6.6 79 2 0.5 16/0.2 9.0 105 4 0.5 16/0.2 9.8 145 1 0.75 24/0.2 9.5 115 2 0.75 24/0.2 10.3 135 4 0.75 24/0.2 11.6 182 1 1 30/0.2 11.5 125 2 1 30/0.2 12.5 150 4 1 30/0.2 13.5 180
FRL-MVB-02YCH-OS-xPyS 300/500V :
-
No.of pair
xNominal Cross Sectional Area
yNumber & Nominal
Diameter of StrandsNominal Overall Diameter Nominal Weight mm2 No/mm mm kg/km 1 0.22 7/0.2 4.2 55 2 0.22 7/0.2 5.9 75 4 0.22 7/0.2 6.2 115 1 0.5 16/0.2 6.3 75 2 0.5 16/0.2 8.5 100 4 0.5 16/0.2 9.4 140 1 0.75 24/0.2 9.0 110 2 0.75 24/0.2 9.7 130 4 0.75 24/0.2 11.1 178 1 1 30/0.2 11.0 120 2 1 30/0.2 12.0 145 4 1 30/0.2 13.0 175
Corona Resistant |
Highly Flexible |
UV Resistant |
Ozone Resistant | Abrasion Retardant |
Cold- resistant |
Resistance To Soldering Heat |
Acid&Alkaline Resistant |
IRM 903 Fuel Oil Resistant |
IRM 902 Mineral Oil Resistant |
Fire Retardant NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4 |
Flame Retardant NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1 |
Low Toxicity NF X70-100/NF F63 808 TM1-04/BS 6853 |
Low Corrosivity IEC60754-2/EN50267-2-2/3 NF C32-074/VDE 0472-813 |
Low Smoke Emission IEC 61034-2 / EN 50268-2 NF C32-073/VDE 0472-816 |
Zero Halogen IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815 |